Live Cell Incubating System

  • Overview
  • Applications
  • Components
  • Specifications
  • Related Products
  • Resources
  • Demo Request

Stage-top Incubator System T

Incubator System T is an intuitive and integrated system, maintains all essential parameters in a physiological state ensures optimal experimental conditions for cell viability on the microscope for the purpose of ‘ happiness for the cells and success for researchers.’

It provides precisely controlled conditions including optimized temperature, humidity, CO₂, and optional O₂ levels for a long-term live cell imaging with various Magnetic Imaging Chambers fitted perfectly. Temperature of main body, incubator cover, humidifier, lens warmer, and gas concentration is controllable and recordable. The gas gradients are programmable by CCP(Computer Controlled Program) software.

Features

Automatic Sensing Mode

Temperature control by 3 types of heating feedback

External Mode [World-Wide 1st]

The optimal temperature control algorithm that minimizes temperature deviation by detecting changes in the temperature outside the incubator automatically adjusts the temperature of the incubator optimized for cell growth.

Sample Mode

By sensing the sample temperature, the optimum incubator temperature is adjusted.

Manual Mode

By setting the temperature desired by the user, various environments for researchers’ purpose can be performed.

Applications

Applications

Localization
Cell differentiation
Cell viability & Cytotoxicity
Phagocytosis & Cell Fusion
Neurite outgrowth/process extension

Live cell imaging of lysis granule dynamics.

To visualize the lysing granules, NK cells in microwells were incubated with 1 μM LysoSensor™ Green DND-189 (Invitrogen, diluted in cell culture medium) for 30 min at 37°C. For live cell imaging, a cover slip containing microwells containing NK cells mounted in a Chamlide chamber (Live Cell Instrument, Korea) is equipped with a Chamlide TC incubator system maintaining 37 °C and 5% CO2 (Live Cell Instrument)
Kim, M., et al., Multi-cellular natural killer (NK) cell clusters enhance NK cell activation through localizing IL-2 within the cluster. Scientific reports, 2017. 7: p. 40623.

Analysis of cardiomyocyte contractility.

Cell contraction was measured using defocusing microscopy (DM), a technique developed by Agero and colleagues (1, 2). Time-lapse microscopy was used to  determine the beating rate of cardiomyocytes. Cells were visualized using a Nikon Eclipse Ti inverted microscope coupled to a 40 Nikon Japan objective lens  with a 0.55 numerical aperture and 2.1 mm working distance.  A Chamlide model CU-109 CO2 incubator (Live Cell Instrument, Seoul, Korea) was used to maintain the samples at 37°C, 5% CO2, and 60% humidity.
Kim, M., et al., Multi-cellular natural killer (NK) cell clusters enhance NK cell activation through localizing IL-2 within the cluster. Scientific reports, 2017. 7: p. 40623.av

Live-cell imaging of intestinal organoids from human induced pluripotent stem cells.

Live-cell imaging of Human intestinal organoids (hIOs) was performed on a motorized inverted microscope with an on-stage incubator (Live Cell Instrument, Seoul, South Korea). Time-lapse images were acquired every 1 h for 48 h.
Jung, K.B., et al., In vitro and in vivo imaging and tracking of intestinal organoids from human induced pluripotent stem cells. The FASEB Journal, 2017. 32(1): p. 111-122.

Time-lapse microscopy of oocyte maturation.

After cRNA injection, oocytes were arrested at the GV stage for 3–4 h in the presence of 2.5 mM milrinone, transferred to freshM16 medium, and cultured for 14 h. Images were capturedat 300- or 600-s intervals for 12–15 h using a widefield fluorescence microscope (Lumascope 620; Etaluma, Carlsbad, CA, USA) or a confocal laser-scanning microscope equipped with a Plan Apochromat 340 1.2 NA water immersion objective and a Chamlide observation chamber and incubator system (Live Cell Instrument, Seoul, South Korea) in M16 medium at 37°C in 5% CO2.
Lee, I.-W., et al., Distinct roles of Cep192 and Cep152 in acentriolar MTOCs and spindle formation during mouse oocyte maturation. The FASEB Journal, 2017. 32(2): p. 625-638.
For live-cell imaging, phagocytosis assays were performed using a stage incubator (Live Cell Instrument) set at 37°C/5% CO2.
Naufer, A., et al., pH of endophagosomes controls association of their membranes with Vps34 and PtdIns (3) P levels. J Cell Biol, 2017: p. jcb. 201702179.
Ledderose, C., et al., Purinergic P2X4 receptors and mitochondrial ATP production regulate T cell migration. The Journal of clinical investigation, 2018.

Components

Incubator

Incubator offers optimal on-stage cell culture environment by maintaining the temperature, humidity, and pH during time lapse imaging. Thermal design of the incubating cover and body are designed to provide heat inside the incubator. For better heat insulation and durability, the incubator body is designed with heating plate to maintain the temperature, while incubator cover composed of built-in dual layered glass traps the heat inside.

Dual-layered incubator cover for heat insulation
Tempered glass for breakage-free using Gorilla 6 Glass
Magnet supporting attachment
Sliding & Whole opening cover
3-channel fluidics port
Temperature control by 3 types of heating feedback
Easy sample insertion by 4-handle Adapter Frame
Fit to 26mm & 30mm W.D. of condenser
Sample holder with Magnet Fixing Cover of Fixing Clip

* ITO Glass & Gorilla Glass 6 (Corning company)

: To improve heat insulation & glass durability

Water Reservoir Type Sample Holder

The water reservoir around the sample holder improves the maintenance of humidity, preventing media from evaporation.
5 Types

Controller

Temperature Controller

Provides stable and precise control of sample temperature for long-term imaging. Using PID Control, it enables maintaining the temperature of all heating parts including incubator cover, incubator main body, humidifier, and lens-warmer

3 types of heating control : External, Sample (K-type), Manual sensing feedback
4 heating channels: Incubator cover, body, humidifier, lens warmer
Simple cable attachment with color connector
Stable and durable temperature distribution
Real-time graph and alarm function
Real-time thermal response
PID control of all parameters

Gas Mixer

Provides accurate concentration gas of CO2, N2, or O2 for research application

Available with 3 types of gas controller
Solenoid valve and a reservoir for uniform gas blends
PID control system regulates gas concentration
Internal air pump for a stable gas flow
Straight quick connection by tubing fittings

* Magnetic attachment cable

Patent Magnetic Connenction
Easy installation
Intuitive connection

Humidifier

The role of the humidifier is to generate and help incubator to maintain relative humidity, and prevent evaporation which can cause cell damage. CO2 gas flows into incubator through heated water controlled by the humidifier sensor. The rate of air-bubbling can be used to check the flow of gas.

Keeps saturated humidity in the incubator
Maintains osmolality of medium by preventing evaporation
Internal thermal sensor for accurate feedback
Detect flow of gas by air-bubbling
Magnetic connector

Lens Warmer

For high-resolution imaging, it is necessary to control the temperature of the immersion objective lens. Oil, glycerin, or water acts as a thermal coupling medium which draws heat away from the specimen. To avoid heat loss, wrap the lens warmer onto the objective lens to generate and maintain a proper temperature. Its silicone band fits to all types of objectives.

For high-magnification & high-resolution imaging
Uses magnetic attachment technique prevents cord breakage by tangling or over tension
Specialized silicone material heating band wraps the lens without gap, preventing thermal dissipation from sample temperature
Flexible silicone material heating band fit to all objective lens

Remote Touch Pad

Android tablet PC provides intuitive graphical screen for all of parameters required to control incubator system

Controls system and all parameters by smartphone and other devices
Provides on-line troubleshooting
Uses GUI(Graphical User Interface) with intuitive and easy control
GUI for real-time temperature and control
Automatically save and check real-time data with PC
Output data to PC through USB A cable

Graphical User Interface

The Incubator System T is an intuitive and user-friendly operator, which can be remote-controlled by smartphones and other mobile devices through app. The operator controls all parameters for the system anytime & anywhere in real time.

Initial Window

1. Incubator Setting
Access the main control panel for all parameters setting
Interface
2. Graph
Real-time graphs show temperature reading for all electrical elements
Interface
3. pH Reference
Screen indicates the current state of sample pH by pH color table (phenol red)
Interface
4. Manual & Support
Download documents you need
Interface
5. Contact
Find company info
Interface

Specification

Incubator

Specification
Dimension 171.5(W) x 139(D) x 15.5(H) mm
Dimension (Incubator Body) 170(W) x 124.5(D) x 20(H) mm
170(W) x 124.5(D) x 24(H) mm
Glass Dual Glass
- Gorilla 6
- ITO heating glass
Weight 250g (Incubator cover)
155g (Incubator body, 26mm)
196g (Incubator body, 30mm)
Cable Type Magnet

Temperature Controller

Specification
Dimension 220(W) x 300(D) x 100(H) mm
Operation Touch Pad
Weight 3.24kg
Temperature Range Ambient +3℃~70℃
SV Resolution 0.1℃
Sensor PT 100ohm (5ea)
Thermocouple sensor (K-type)
Control Method PID
Volume Humidifier 90cc
Volume Reservoir 25cc
Power 100~240V

Gas Mixer

Specification
Dimension 220(W) x 300(D) x 100(H) mm
Operation Touch Pad
Weight 4.44kg
Gas Type 100% CO2 5% CO2
Input Gas Pressure 0.12Mpa
Concentration Range CO2 1~20%
O2 1~99%
Accuracy ±0.1%
SV Resolution 0.1%
Flow Rate Max 200ml/min
Sensor CO2 NDIR
O2 Thermal conductive
N2 Thermal conductive
Control Method PID
Control Valve CO2 Solenoid valve
O2 Proportional Solenoid orifice
N2 Proportional Solenoid orifice
Power 100~240V

*: Only applies to OX series(OX-10, OX-10H)

Related Products

Resource

전체 5
Incubator System T_leafletIncubator System
2021.03.10 2021.03.10
Customization Order
Download Literature
Demo Request

Available with various chamber types

Magnetic attachment cable

Patent magnetic connection
E-asy installation
Intuitive connection

Touch pad control

8 inch wider touch pad
Easy to control

Sliding incubator cover

Whole open incubator cover